OEM wind power air-insulated busbar

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-09-04 11:05

  • Browse the number:

    106

Send an inquiries
Company Profile
Suzhou Kiande Electric Co.,Ltd
Contactaixin:

kiande(Ms.)  

telephone:

Arrea:

Beijing

Address:

Room 479, 1# Building, No.10, East of Nanhuan Road, Wuzhong, Suzhou, Jiangsu, China (215000)

Website:

http://kiande.carpetcleaninginchester.com/

Product details

Model Number: KD-02-01-#0497 Key Specifications/Special Features: SpecificationsAir-insulated typeThe environmental protection materialsIP ratings up to IP54System introductionWind power busbar (here after refers to busduct) is applied for wind power unit with 750kW or above generation capabilityAir-insulated type
  • Environmental protection index of original materials can meet the requirements of RoHS Directive-compliant
  • IP ratings up to IP54
  • Product usage life is over 40 years
  • Tightening bolt with low temperature resistant alloy material
  • Rated voltage: 690V Insulation voltage: 1000V
  • Better performance price ratio than wind power
  • Wind Type 1.5/2mW double feeder wind power unit
    Busduct Type WLK WLH
    Standard IEC60439-1, 2:GB7251.1, 2
    Environmental Temperature -40 to +50°C
    IP Ratings IP31, IP40, IP54 (optional)
    Rated Insulation voltage (AC,V) 1000/1500
    Rated working voltage (AC,V) 690/1000 690/1000
    Rated Working Current (A) 1300, 1400, 1800, 2000(optional) 500, 630, 800(optional)
    Rated Peak Tolerance Current (kV) 105 to 176 63 to 85
    Rated Short-term Tolerance Current (kV) 50 to 80 30 to 40
    Rated Frequency(Hz) 50 to 60
    Air clearance Between energized conductors ≥20 ≥20
    Between energized conductor and enclosure ≥18 ≥18
    Cree page distance Between energized conductors ≥25 ≥25
    Between energized conductor and enclosure ≥22 ≥22
    The high-point of temperature riseon connections of busbar (K) 70 70
    The high-point of temperature rise on tangible enclosures and covers (K) 30 30
    Material group Two
    Overvoltage categories Four
    Pollution degree Three
    Protect Type First
    Wire L1+L2+L3+pen
    Dielectric Strength(V/min) 3750/AC, 1min
    Insulation Resistance (MΩ) ≥20(phase-to-phase or phase-to-ground, 1000mΩ)
    Main Export Markets:
    • Asia
    • Eastern Europe
    • Mid East/Africa